{"id":4918,"date":"2025-06-10T14:13:50","date_gmt":"2025-06-10T05:13:50","guid":{"rendered":"https:\/\/asahi-xray.co.jp\/global\/?post_type=product&#038;p=4918"},"modified":"2025-10-29T13:29:27","modified_gmt":"2025-10-29T04:29:27","slug":"solio-xzii","status":"publish","type":"product","link":"https:\/\/asahi-xray.co.jp\/global\/product\/solio-xzii\/","title":{"rendered":"CT X-ray Equipment <br>SOLIO X Series"},"content":{"rendered":"<div class=\"product-single-icatch\">\n  <img\n    class=\"pc maxwidth\"\n    src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/09\/pl_fv-pc-1.jpg\"\n    alt=\"\"\n  \/><img\n    class=\"sp maxwidth solioxzii\"\n    src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/09\/pl_fv-sp-1.jpg\"\n    alt=\"\"\n  \/>\n<\/div>\n<ul class=\"crumb\">\n<li><a href=\"https:\/\/asahi-xray.co.jp\/global\">Home<\/a><\/li>\n<li><a href=\"https:\/\/asahi-xray.co.jp\/global\/product\">Product<\/a><\/li>\n<li>Arm-type X-ray CT diagnostic instrument SOLIO X Series<\/li>\n<\/ul>\n<div class=\"solio-xz2\">\n<div class=\"product-contents-wrap page-contents\">\n<section class=\"product-single-contents-wrap product-detail\">\n<h1>\n        Arm-type X-ray CT diagnostic instrument<br class=\"sp\" \/><br \/>\n        SOLIO X Series<br \/>\n      <\/h1>\n<h2>IMPROVED IMAGE QUALITY<\/h2>\n<p class=\"lead\">\n        By integrating a new sensor, even clearer panoramic and CT images are<br \/>\n        now possible.<br \/>\n        The obtained panoramic images are ideal for full-mouse screenings,<br \/>\n        whereas the CT images, through 3D scanning, are for detailed diagnoses<br \/>\n        of teeth and bones from all aspects.<br \/>\n        Enhanced panoramic imaging, the foundation of dental treatment, combined<br \/>\n        with high resolution CT imaging for detailed diagnosis, has transformed<br \/>\n        the way we work. We can see more, diagnose with confidence, and truly<br \/>\n        embrace Imaging New Visions.\n      <\/p>\n<div class=\"movie-wrap product-read\" style=\"margin: 30px 0px 0\">\n        <iframe\n          src=\"https:\/\/www.youtube.com\/embed\/aY30MmEyJ90\"\n          frameborder=\"0\"\n          allow=\"accelerometer; autoplay; encrypted-media; gyroscope; picture-in-picture\"\n          allowfullscreen=\"\"\n        ><\/iframe>\n      <\/div>\n<p class=\"video-caution\">*This video is in Japanese only.<\/p>\n<\/section><\/div>\n<ul class=\"special pc\">\n<li>\n      <a href=\"#panorama\"\n        ><img\n          class=\"tit01\"\n          src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/07\/1-1.png\"\n          alt=\"\" \/><img\n          class=\"det01\"\n          src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/07\/4-1.png\"\n          alt=\"\" \/><span><\/span\n      ><\/a>\n    <\/li>\n<li>\n      <a href=\"#ct\"\n        ><img\n          class=\"tit02\"\n          src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/07\/2-1.png\"\n          alt=\"\" \/><img\n          class=\"det02\"\n          src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/07\/5-1.png\"\n          alt=\"\" \/><span><\/span\n      ><\/a>\n    <\/li>\n<li>\n      <a href=\"#cephalo\"\n        ><img\n          class=\"tit03\"\n          src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/07\/3-1.png\"\n          alt=\"\" \/><img\n          class=\"det03\"\n          src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/07\/6-1.png\"\n          alt=\"\" \/><span><\/span\n      ><\/a>\n    <\/li>\n<\/ul>\n<ul class=\"specialsp sp\">\n<li>\n<div class=\"tit\">\n        <img\n          src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/07\/1-1.png\"\n          alt=\"\"\n        \/>\n      <\/div>\n<div class=\"detail\">\n        <a href=\"#solio-01\"\n          ><img\n            src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/07\/sp_sp1.png\"\n            alt=\"\" \/><span><\/span\n        ><\/a>\n      <\/div>\n<\/li>\n<li>\n<div class=\"tit\">\n        <img\n          src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/07\/2-1.png\"\n          alt=\"\"\n        \/>\n      <\/div>\n<div class=\"detail\">\n        <a href=\"#solio-02\"\n          ><img\n            src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/07\/sp_sp2.png\"\n            alt=\"\" \/><span><\/span\n        ><\/a>\n      <\/div>\n<\/li>\n<li>\n<div class=\"tit\">\n        <img\n          src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/07\/3-1.png\"\n          alt=\"\"\n        \/>\n      <\/div>\n<div class=\"detail\">\n        <a href=\"#solio-03\"\n          ><img\n            src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/07\/sp_sp3.png\"\n            alt=\"\" \/><span><\/span\n        ><\/a>\n      <\/div>\n<\/li>\n<\/ul>\n<p>  <!-- \u3053\u3053\u304b\u3089\u66f8\u304d\u76f4\u3057 --><br \/>\n  <main><\/p>\n<section class=\"sec sec--highlight\" id=\"panorama\">\n<div class=\"hd\">\n<h2 class=\"heading\">PANORAMA<\/h2>\n<div class=\"time\">\n          <img\n            src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/07\/7.jpg\"\n            alt=\"\"\n          \/>\n        <\/div>\n<\/p><\/div>\n<div class=\"block-wrap\">\n<div class=\"block\">\n<h3 class=\"block__ttl\">\n            Integrated optimized sensor for panoramic images<br \/>\n          <\/h3>\n<div class=\"block__img block__img--60\">\n            <img\n              src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/08\/table.jpg\"\n              alt=\"\"\n            \/>\n          <\/div>\n<\/p><\/div>\n<div class=\"block\">\n<h3 class=\"block__ttl\">AF (Asahi Fine) Panorama<\/h3>\n<div class=\"block__txt\">\n            By combining the three features: Noise Reduction, Sharpening and<br \/>\n            Focal Composition, our newly developed image processing algorithm<br \/>\n            gives clearer images.\n          <\/div>\n<div class=\"item-wrap\">\n<div class=\"item\">\n<div class=\"item__img\">\n                <img\n                  src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/08\/04.jpg\"\n                  alt=\"\"\n                \/>\n              <\/div>\n<\/p><\/div>\n<div class=\"item\">\n<div class=\"item__img\">\n                <img\n                  src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/08\/05.jpg\"\n                  alt=\"\"\n                \/>\n              <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"block\">\n<h3 class=\"block__ttl\">Focal Composition<\/h3>\n<div class=\"block__txt\">\n            Dual-image processing technology has been introduced for composite<br \/>\n            panoramic images constructed from multiple tomographic planes to<br \/>\n            enhance the clarity of the contours in any part of the image.\n          <\/div>\n<p>          <!-- \n\n<div class=\"block__img block__img--50\">\n            <img\n              src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/08\/01.jpg\"\n              alt=\"\"\n            \/>\n          <\/div>\n\n --><\/p>\n<div class=\"item-wrap\">\n<div class=\"item\">\n<div class=\"item__img\">\n                <img\n                  src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/08\/01.jpg\"\n                  alt=\"\"\n                \/>\n              <\/div>\n<\/p><\/div>\n<div class=\"item\">\n<div class=\"item__img\">\n                <img\n                  src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/08\/02.jpg\"\n                  alt=\"\"\n                \/>\n              <\/div>\n<div class=\"item__txt\">Normal panoramic images<\/div>\n<\/p><\/div>\n<div class=\"item\">\n<div class=\"item__img\">\n                <img\n                  src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/08\/03.jpg\"\n                  alt=\"\"\n                \/>\n              <\/div>\n<div class=\"item__txt\">Focal Composition processed<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"block\">\n<h3 class=\"block__ttl\">Tomosynthesis<\/h3>\n<div class=\"block__txt\">\n            The tomosynthesis mode allows panoramic images of a slice thickness<br \/>\n            of 30 mm and optimizes the image by adjusting the blurred area at<br \/>\n            the anterior teeth. As clearer images are always available, no<br \/>\n            repeated exposure is required even after misaligned processes.\n          <\/div>\n<div class=\"block__caution\">\n            *Children need to have different focal areas for panoramic images.\n          <\/div>\n<div class=\"item-wrap\">\n<div class=\"item\">\n<div class=\"item__img\">\n                <picture><source \nmedia=\"(min-width: 769px)\"\n                    srcset=\"\n                      https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/08\/61246778759683db699c8bae288df2e1.jpg\n                    \"\n                  \/><source \nmedia=\"(max-width: 768px)\"\n                    srcset=\"\n                      https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/08\/sp-2.jpg\n                    \"\n                  \/><br \/>\n                  <img\n                    src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/08\/61246778759683db699c8bae288df2e1.jpg\"\n                    alt=\"\"\n                  \/>\n                <\/picture>\n              <\/div>\n<div class=\"item__txt-wrap\">\n<div class=\"item__txt\">\n                  Optimized slice position images are automatically displayed<br \/>\n                  from the image data of an area with a slice thickness of 30<br \/>\n                  mm.\n                <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"item\">\n<div class=\"item__img\">\n                <img\n                  src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/08\/10.jpg\"\n                  alt=\"\"\n                \/>\n              <\/div>\n<div class=\"item__txt-wrap\">\n<div class=\"item__txt\">\n                  As the panoramic imaging trajectory can be adjusted in the<br \/>\n                  anterior and right and left molar regions, images can be<br \/>\n                  optimized according to the shape of the patient&#8217;s dentition.\n                <\/div>\n<div class=\"item__caution\">\n                  *Once saved, the trajectory cannot be corrected.\n                <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"item\">\n<div class=\"item__img\">\n                <picture><source \nmedia=\"(min-width: 769px)\"\n                    srcset=\"\n                      https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/08\/bd2324610defdbfff433a1beebb2d77a.jpg\n                    \"\n                  \/><source \nmedia=\"(max-width: 768px)\"\n                    srcset=\"\n                      https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/08\/sp-1.jpg\n                    \"\n                  \/><br \/>\n                  <img\n                    src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/08\/bd2324610defdbfff433a1beebb2d77a.jpg\"\n                    alt=\"\"\n                  \/>\n                <\/picture>\n                <img src=\"\" alt=\"\" \/>\n              <\/div>\n<div class=\"item__txt-wrap\">\n<div class=\"item__txt\">\n                  Clearer images can be generated from 31 images with a thinner<br \/>\n                  slice thickness of 1 mm.\n                <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"block\">\n<h3 class=\"block__ttl\">Partial panorama<\/h3>\n<div class=\"block__txt\">\n            Limiting exposure to specific areas is possible by eliminating<br \/>\n            unnecessary radiation. This approach is particularly effective for<br \/>\n            patients who experience difficulties when undergoing dental imaging<br \/>\n            procedures due to involuntary choking reflexes or other reactions.\n          <\/div>\n<div class=\"item-wrap\">\n<div class=\"item\">\n<div class=\"item__img\">\n                <picture><source \nmedia=\"(min-width: 769px)\"\n                    srcset=\"\n                      https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/08\/grf.jpg\n                    \"\n                  \/><source \nmedia=\"(max-width: 768px)\"\n                    srcset=\"\n                      https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/08\/haa.jpg\n                    \"\n                  \/><br \/>\n                  <img\n                    src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/08\/grf.jpg\"\n                    alt=\"\"\n                  \/>\n                <\/picture>\n              <\/div>\n<\/p><\/div>\n<div class=\"item\">\n<div class=\"item__img\">\n                <img\n                  src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/08\/06.jpg\"\n                  alt=\"\"\n                \/>\n              <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/section>\n<section class=\"sec sec--highlight\" id=\"ct\">\n<div class=\"hd\">\n<h2 class=\"heading\">CT<\/h2>\n<div class=\"time\">\n          <img\n            src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/07\/12.jpg\"\n            alt=\"\"\n          \/>\n        <\/div>\n<\/p><\/div>\n<div class=\"block-wrap\">\n<div class=\"block\">\n<h3 class=\"block__ttl\">\n            High Definition CT Images Takes Only 12 sec<br \/>\n          <\/h3>\n<div class=\"block__txt\">\n            12 sec for 360-degree full-scan CT images, and 6 sec for 180-degree<br \/>\n            CT images. Our shortest imaging time ever, without compromising<br \/>\n            image quality.\n          <\/div>\n<\/p><\/div>\n<div class=\"block\">\n<h3 class=\"block__ttl\">\n            360-degree Exposure Realizing Clear Image Quality<br \/>\n          <\/h3>\n<div class=\"block__txt\">\n            To minimize image artifacts caused by the presence of metal, we have<br \/>\n            introduced a 360-degree rotational shooting system. The larger the<br \/>\n            rotation angle, the less impact on the image due to artifacts,<br \/>\n            resulting in a crisp high-definition CT image.\n          <\/div>\n<div class=\"block__caution\">\n            *A rotation angle of 270 degrees is possible according to the<br \/>\n            patient\u2019s positioning.\n          <\/div>\n<div class=\"block__img block__img--30\">\n            <img\n              src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/08\/fov.jpg\"\n              alt=\"\"\n            \/>\n          <\/div>\n<div class=\"block__caution\">\n            FOV (I-mode) coverage up to the third molar apex\n          <\/div>\n<\/p><\/div>\n<div class=\"block\">\n<h3 class=\"block__ttl\">Exposure Mode, Field of Vision (FOV)<\/h3>\n<div class=\"item-wrap\">\n<div class=\"item\">\n<div class=\"item__img\">\n                <img\n                  src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/08\/i.jpg\"\n                  alt=\"\"\n                \/>\n              <\/div>\n<div class=\"item__txt-wrap\">\n<div class=\"item__ttl\">D-mode<\/div>\n<div class=\"item__txt\">\n                  \u042451 \u00d7 55 (H) mm<br \/>\n                  Voxel size: 100 \u03bcm\n                <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"item\">\n<div class=\"item__img\">\n                <img\n                  src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/08\/i-1.jpg\"\n                  alt=\"\"\n                \/>\n              <\/div>\n<div class=\"item__txt-wrap\">\n<div class=\"item__ttl\">I-mode<\/div>\n<div class=\"item__txt\">\n                  \u042498 \u00d7 100 (H) mm<br \/>\n                  Voxel size: 177 \u03bcm\n                <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"block\">\n<h3 class=\"block__ttl\">\n            NEODYNA MAR<br \/>\n            <span class=\"block__ttl--small\"><br \/>\n              (with reduced metal-induced artifacts)<br \/>\n            <\/span><br \/>\n          <\/h3>\n<div class=\"block__txt\">\n            Our proprietary MAR algorithm reduces image artifacts caused by<br \/>\n            metal implants and other objects. As well as 360-degree image<br \/>\n            acquisition, images can be obtained that are less affected by<br \/>\n            artifacts.\n          <\/div>\n<div class=\"block__img block__img--100\">\n            <picture><source \nmedia=\"(min-width: 769px)\"\n                srcset=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/themes\/asashi\/img\/product\/solio-xz-02-05.jpg\"\n              \/><source \nmedia=\"(max-width: 768px)\"\n                srcset=\"\n                  https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/08\/gre.jpg\n                \"\n              \/><br \/>\n              <img src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/themes\/asashi\/img\/product\/solio-xz-02-05.jpg\" alt=\"\" \/>\n            <\/picture>\n          <\/div>\n<\/p><\/div>\n<div class=\"block\">\n<h3 class=\"block__ttl\">NEOSMART<\/h3>\n<div class=\"block__txt\">Sharpened &#8211; Scattered ray correction<\/div>\n<div class=\"block__caution\">\n            Stabilizes the brightness values of hard tissues\n          <\/div>\n<div class=\"block__txt\">Smooth &#8211; Beam hardening correction<\/div>\n<div class=\"block__caution\">\n            Decreases image artifacts between tooth implants.\n          <\/div>\n<p>          <!-- \n\n<div class=\"block__txt\">\n            Sharpened - Scattered ray correction<br \/>\n            stabilizes the brightness values of hard tissues\n\n\n            Smooth - Beam hardening correction<br \/>\n            decreases image artifacts between tooth implants.\n          <\/div>\n\n -->\n        <\/div>\n<div class=\"block\">\n<h3 class=\"block__ttl\">Part Reconstruction Function<\/h3>\n<div class=\"block__txt\">\n            Without the necessity of re-exposure, a high-precision image of the<br \/>\n            region of interest can be obtained.\n          <\/div>\n<table>\n<thead>\n<tr>\n<th><\/th>\n<th>Normal exposure<\/th>\n<th>Part Reconstruction applied<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th>D-mode<\/th>\n<td>\n                  \u00d851\u00d755 (H) mm<br \/>\n                  Voxel size: 100 \u03bcm\n                <\/td>\n<td>\n                  \u00d840\u00d750 (H) mm<br \/>\n                  Voxel size: 75 \u03bcm\n                <\/td>\n<\/tr>\n<tr>\n<th rowspan=\"2\">I-mode<\/th>\n<td rowspan=\"2\">\n                  \u00d898\u00d7100 (H) mm<br \/>\n                  Voxel size: 177 \u03bcm\n                <\/td>\n<td>\n                  \u00d851\u00d754 (H) mm<br \/>\n                  Voxel size: 100 \u03bcm\n                <\/td>\n<\/tr>\n<tr>\n<td>\n                  \u00d840\u00d750 (H) mm<br \/>\n                  Voxel size: 75 \u03bcm\n                <\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<div class=\"block\">\n<h3 class=\"block__ttl\">NEODYNA MAR \/ NEOSMART<\/h3>\n<div class=\"block__caution\">\n            *This function is available only in \u201cNEOPREMIUM2\u201dsoftware\n          <\/div>\n<div class=\"block-wrap\">\n<div class=\"block\">\n<div class=\"block__img\">\n                <picture><source \nmedia=\"(min-width: 769px)\"\n                    srcset=\"\n                      https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/08\/0218efccfa565d4d2ee80984bd2a639e.jpg\n                    \"\n                  \/><source \nmedia=\"(max-width: 768px)\"\n                    srcset=\"\n                      https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/08\/fwdscfdv.jpg\n                    \"\n                  \/><br \/>\n                  <img\n                    src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/08\/0218efccfa565d4d2ee80984bd2a639e.jpg\"\n                    alt=\"\"\n                  \/>\n                <\/picture>\n              <\/div>\n<div class=\"block__txt-wrap\">\n<div class=\"block__caution\">\n                  Gingival root (permanent maxillary right second molar),<br \/>\n                  impacted wisdom tooth\n                <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"item-wrap\">\n<div class=\"item\">\n<div class=\"item__img\">\n                <img\n                  src=\"https:\/\/asahi-xray.co.jp\/wp\/wp-content\/themes\/asashi\/img\/product\/solio-xz-02-08.jpg\"\n                  alt=\"\"\n                \/>\n              <\/div>\n<div class=\"item__txt-wrap\">\n<div class=\"item__txt\">Apical periodontitis<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"item\">\n<div class=\"item__img\">\n                <img\n                  src=\"https:\/\/asahi-xray.co.jp\/wp\/wp-content\/themes\/asashi\/img\/product\/solio-xz-02-09.jpg\"\n                  alt=\"\"\n                \/>\n              <\/div>\n<div class=\"item__txt-wrap\">\n<div class=\"item__txt\">Impacted supernumerary tooth<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"item-wrap\">\n<div class=\"item\">\n<div class=\"item__img\">\n                <img\n                  src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/08\/cdb2fe6faa93f8fa81c52d2ef4b525f5.jpg\"\n                  alt=\"\"\n                \/>\n              <\/div>\n<div class=\"item__txt-wrap\">\n<div class=\"item__txt\">\n                  Enlargement of the periodontal cavity\n                <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"item\">\n<div class=\"item__img\">\n                <img\n                  src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/08\/4495a33bcbab8d9bb97fd8d63512acf2.jpg\"\n                  alt=\"\"\n                \/>\n              <\/div>\n<div class=\"item__txt-wrap\">\n<div class=\"item__txt\">Cyst<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/section>\n<section class=\"sec sec--highlight\" id=\"cephalo\">\n<div class=\"hd\">\n<div class=\"heading-wrap\">\n<h2 class=\"heading\">One-shot CEPHALO<\/h2>\n<div class=\"caution\">\n            *SOLIO XZII MAXIM \/ Specifications with Cephalometric Exposure\n          <\/div>\n<\/p><\/div>\n<div class=\"time\">\n          <img\n            src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/08\/1sec.jpg\"\n            alt=\"\"\n          \/>\n        <\/div>\n<\/p><\/div>\n<div class=\"block-wrap\">\n<div class=\"block\">\n<h3 class=\"block__ttl\">\n            76 \u03bcm Pixel Size, Giving our Highest Image Quality yet<br \/>\n          <\/h3>\n<div class=\"block__img block__img--20\" style=\"max-width: 173px\">\n            <img\n              src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/07\/16.jpg\"\n              alt=\"\"\n            \/>\n          <\/div>\n<div class=\"block__txt\">\n            Equipped with a new cephalometric FPD sensor with a pixel size of<br \/>\n            just 76 \u03bcm, SOLIO XZII now offers significantly higher resolution.<br \/>\n            This makes it possible to obtain more detailed images for easier<br \/>\n            diagnosis. Furthermore, the line pair resolution* has also been<br \/>\n            improved by approx. 1.7 times compared to the FPD sensors in our<br \/>\n            other models.\n          <\/div>\n<div class=\"block__caution\">\n            *Resolution is indicated by the number of black and white line pairs<br \/>\n            per mm that can be distinguished.\n          <\/div>\n<\/p><\/div>\n<div class=\"block\">\n<h3 class=\"block__ttl\">One-shot Exposure for a Second or Less<\/h3>\n<div class=\"block__txt\">\n            With a one-shot exposure time of only 1.0 second maximum, you can<br \/>\n            image confidently without being affected by your patient\u2019s body<br \/>\n            movement. The shorter exposure time reduces the X-ray dose of<br \/>\n            patients, children in particular. Also, there should be no image<br \/>\n            blurring as a result of the sensor inadvertently contacting the<br \/>\n            patient\u2019s shoulder -which is often an issue during line scanning.\n          <\/div>\n<div class=\"block__img block__img--100\">\n            <img src=\"\" alt=\"\" \/>\n            <picture><source \nmedia=\"(min-width: 769px)\"\n                srcset=\"\n                  https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/08\/gazou.jpg\n                \"\n              \/><source \nmedia=\"(max-width: 768px)\"\n                srcset=\"\n                  https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/08\/twgsdv.jpg\n                \"\n              \/><br \/>\n              <img\n                src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/08\/gazou.jpg\"\n                alt=\"\"\n              \/>\n            <\/picture>\n          <\/div>\n<div class=\"block__caution\">\n            *1 Cephalometric exposure for 1.0 sec (side): with the sensor used<br \/>\n            laterally<br \/>\n            *2 Cephalometric exposure for 1.0 sec (front): with the sensor<br \/>\n            oriented vertically<br \/>\n            *3 Bone of Carpus for 1.0 sec (Optional)\n          <\/div>\n<\/p><\/div>\n<div class=\"block\">\n<h3 class=\"block__ttl\">Comparison with Scanning Method<\/h3>\n<div class=\"item-wrap\">\n<div class=\"item\">\n<div class=\"item__img\">\n                <img\n                  src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/08\/330cf155b7e5fdff3ce40a1110a5cffd.jpg\"\n                  alt=\"\"\n                \/>\n              <\/div>\n<div class=\"item__txt-wrap\">\n<div class=\"item__txt\">SOLIO XZII MAXIM<\/div>\n<div class=\"item__caution\">Pixel size: 76 \u03bcm (1 sec)<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"item\">\n<div class=\"item__img\">\n                <img\n                  src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/08\/7ccb5ef74b1b3a60cf178b5a2547c571.jpg\"\n                  alt=\"\"\n                \/>\n              <\/div>\n<div class=\"item__txt-wrap\">\n<div class=\"item__txt\">\n                  Panoramic X-ray unit our conventional CCD sensor\n                <\/div>\n<div class=\"item__caution\">Pixel size: 96 \u03bcm (4 sec)<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/section>\n<section class=\"sec\">\n<h2 class=\"heading\">Comfortable Working Environment<\/h2>\n<div class=\"txt\">\n        With a variety of functions such as our original Head Support &#038; Grip and<br \/>\n        CT Positioning System, a comfortable working environment is assured,<br \/>\n        easing the burden on both patient and operator.\n      <\/div>\n<div class=\"block-wrap\">\n<div class=\"block\">\n<h3 class=\"block__ttl\">\n            User-friendly &#038; Comfortable Setting of the Exposure Area for CT<br \/>\n            Images<br \/>\n          <\/h3>\n<div class=\"block__txt\">\n            Simple CT operations are possible without burdening the patient or<br \/>\n            operator.\n          <\/div>\n<\/p><\/div>\n<div class=\"block\">\n<h3 class=\"block__ttl\">Automatic Setting of Image Exposure Area<\/h3>\n<div class=\"block__txt\">\n            By selecting your desired image area via the connected PC, the<br \/>\n            instrument can automatically move to the image acquisition location.<br \/>\n            Prior positioning in the horizontal plane can be performed before<br \/>\n            introducing the patient.\n          <\/div>\n<div class=\"block__img block__img--40\">\n            <img\n              src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/themes\/asashi\/img\/product\/Dental.jpg\"\n              alt=\"\"\n            \/>\n          <\/div>\n<\/p><\/div>\n<div class=\"block\">\n<h3 class=\"block__ttl\">Preliminary Imaging Function<\/h3>\n<div class=\"block__txt\">\n            The preliminary imaging function enables directional adjustment of<br \/>\n            the CT capture area forwards, backwards, left, right, and up &#038; down.<br \/>\n            This greatly assists obtaining an accurate and reliable position<br \/>\n            setting. After setting, the CT mechanism automatically moves to the<br \/>\n            targeted position for trouble-free image acquisition. This prevents<br \/>\n            errors due to incorrect positioning and avoids repetition of CT<br \/>\n            imaging operations.\n          <\/div>\n<div class=\"block__img block__img--50\">\n            <img\n              src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/themes\/asashi\/img\/product\/solio-xz-dt-02.png\"\n              alt=\"\"\n            \/>\n          <\/div>\n<div class=\"block__movie\">\n            <iframe\n              src=\"https:\/\/www.youtube.com\/embed\/5TxyJoHm08s\"\n              title=\"YouTube video player\"\n              frameborder=\"0\"\n              allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\"\n              allowfullscreen=\"\"\n            ><\/iframe>\n          <\/div>\n<div class=\"block__caution\">*This video is in Japanese only.<\/div>\n<\/p><\/div>\n<div class=\"block\">\n<h3 class=\"block__ttl\">\n            Original Head-support &#038; Grip Assures Correct Positioning for<br \/>\n            Panoramic Exposures<br \/>\n          <\/h3>\n<div class=\"block__txt\">\n            Total 7-point support including 2 points on the patient\u2019s chest, in<br \/>\n            addition to stabilized head positioning. This makes for a steadier<br \/>\n            hold on the patient for clearer images with reduced blur. Also<br \/>\n            possible is panoramic imaging using the correct extended posture for<br \/>\n            the cervical spine. The process of patient position adjustment is<br \/>\n            also smooth, thanks to the minimized part-exchanges required for<br \/>\n            different exposure modes.\n          <\/div>\n<div class=\"block__img block__img--40\">\n            <img\n              src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/themes\/asashi\/img\/product\/solio-xz-dt-03.png\"\n              alt=\"\"\n            \/>\n          <\/div>\n<\/p><\/div>\n<div class=\"block\">\n<h3 class=\"block__ttl\">CT Positioning System<\/h3>\n<div class=\"block__txt\">\n            After positioning a patient, you can perform vertical movement of<br \/>\n            the CT exposure mechanism with a single touch Since it is possible<br \/>\n            to adjust the 100 mm wide CT exposure region up or down without<br \/>\n            moving the patient, the burden on the patient and the operator is<br \/>\n            drastically reduced.\n          <\/div>\n<div class=\"block__img block__img--80\">\n            <img\n              src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/themes\/asashi\/img\/product\/solio-xz-dt-04.png\"\n              alt=\"\"\n            \/>\n          <\/div>\n<div class=\"block__movie\">\n            <iframe\n              src=\"https:\/\/www.youtube.com\/embed\/GvecxaCKMpo\"\n              title=\"YouTube video player\"\n              frameborder=\"0\"\n              allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\"\n              allowfullscreen=\"\"\n            ><\/iframe>\n          <\/div>\n<div class=\"block__caution\">*This video is in Japanese only.<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/section>\n<section class=\"sec\">\n<h2 class=\"heading\">Space-saving, Safe and Secure<\/h2>\n<div class=\"txt\">\n        Our solutions can be installed to make optimum use of space, for safe<br \/>\n        and secure operation over extended periods.\n      <\/div>\n<div class=\"block-wrap\">\n<div class=\"block\">\n<h3 class=\"block__ttl\">\n            780 mm Stroke for Standing and Sitting Positions<br \/>\n          <\/h3>\n<div class=\"block__inner block__inner--3-7\">\n<div class=\"block__img\">\n              <img\n                src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/08\/solio-xz-dt-05.png\"\n                alt=\"\"\n              \/>\n            <\/div>\n<div class=\"block__txt\">\n              With a vertical stroke width of 780 mm, SOLIO XZII caters for a<br \/>\n              wide range of patient positions such as standing, sitting, or<br \/>\n              wheelchair bound.\n            <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"block\">\n<h3 class=\"block__ttl\">Space-saving and Compact CT Imaging System<\/h3>\n<div class=\"block__txt\">\n            SOLIO XZII takes up an area of 1.5 m square, SOLIO XZII MAXIM can be<br \/>\n            installed in an X-ray room of 2.1 m width by 1.5 m depth. It is our<br \/>\n            most compact CT imaging system yet.\n          <\/div>\n<div class=\"block__img block__img--80\">\n            <img\n              src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/uploads\/2025\/08\/31ddc05ad24271b588a007a78868e1f3.jpg\"\n              alt=\"\"\n            \/>\n          <\/div>\n<div class=\"block__movie\">\n            <iframe\n              src=\"https:\/\/www.youtube.com\/embed\/x_QLrWtz6Oc\"\n              title=\"YouTube video player\"\n              frameborder=\"0\"\n              allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\"\n              allowfullscreen=\"\"\n            ><\/iframe>\n          <\/div>\n<div class=\"block__caution\">*This video is in Japanese only.<\/div>\n<\/p><\/div>\n<div class=\"block\">\n<h3 class=\"block__ttl\">\n            Navigating LED illumination on the Operation Panel<br \/>\n          <\/h3>\n<div class=\"block__inner block__inner--3-7\">\n<div class=\"block__img\">\n              <img\n                src=\"https:\/\/asahi-xray.co.jp\/global\/wp\/wp-content\/themes\/asashi\/img\/product\/solio-xz-dt-07.png\"\n                alt=\"\"\n              \/>\n            <\/div>\n<div class=\"block__txt\">\n              All the necessary operation buttons are incorporated into the<br \/>\n              operation panel with a user-friendly, easy-to-see design. With<br \/>\n              these buttons you can move the instrument up\/down, position the<br \/>\n              rotating head to the exposure region, and move the positioning<br \/>\n              beam. Moreover, the LED assistance helps you navigate to the<br \/>\n              required buttons according to the exposure steps.\n            <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"block\">\n<h3 class=\"block__ttl\">Compact Sensor Design and Wide Arm<\/h3>\n<div class=\"block__txt\">\n            The space-saving design of the lower section of the sensor and the<br \/>\n            wide-arm design minimizes the possibility of the rotating mechanism<br \/>\n            contacting the patient\u2019s shoulder during exposure.\n          <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/section>\n<p>  <\/main><\/p>\n<section class=\"product-single-contents-wrap gray-wrap product-relation\">\n<div class=\"inner clm-wrap\">\n<div class=\"text-wrap\">\n<h3>Related products<\/h3>\n<h4>Digital Image Information Software NEOPREMIUM2<\/h4>\n<p>        <a\n          class=\"more\"\n          href=\"https:\/\/asahi-xray.co.jp\/global\/wp\/product\/neopremium2\/\"\n        ><\/a>\n      <\/div>\n<div class=\"thumb-wrap\">\n        <img\n          src=\"https:\/\/asahi-xray.co.jp\/wp\/wp-content\/uploads\/2021\/06\/product_relation_01.png\"\n          alt=\"\"\n        \/>\n      <\/div>\n<\/p><\/div>\n<\/section>\n<\/div>\n","protected":false},"featured_media":5038,"template":"temp_product-2025.php","product_cat":[35,43],"product_new":[47],"product_old":[],"_links":{"self":[{"href":"https:\/\/asahi-xray.co.jp\/global\/wp-json\/wp\/v2\/product\/4918"}],"collection":[{"href":"https:\/\/asahi-xray.co.jp\/global\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/asahi-xray.co.jp\/global\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/asahi-xray.co.jp\/global\/wp-json\/wp\/v2\/media\/5038"}],"wp:attachment":[{"href":"https:\/\/asahi-xray.co.jp\/global\/wp-json\/wp\/v2\/media?parent=4918"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/asahi-xray.co.jp\/global\/wp-json\/wp\/v2\/product_cat?post=4918"},{"taxonomy":"product_new","embeddable":true,"href":"https:\/\/asahi-xray.co.jp\/global\/wp-json\/wp\/v2\/product_new?post=4918"},{"taxonomy":"product_old","embeddable":true,"href":"https:\/\/asahi-xray.co.jp\/global\/wp-json\/wp\/v2\/product_old?post=4918"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}